Skip to content

LinkPoint Connect(ME) Synchronization Error Codes

 

This sync issues table is an addition to the articles one and two on monitoring end users’ synchronization status in LinkPoint Connect(ME) Admin panel.

Error types

SE errors: are registered during a sync session, do not suspend synchronization

SC errors: are caused by problems in configuration, synchronization is stopped

SD errors: appear when invalid data is retrieved from either side; only some of these errors stop synchronization

SI errors: internal sync engine errors

SW errors: statuses listed in the sync dump and log file. If an error occurs on a sync session, this status serves as the error description

 

Error severity levels

(L)ow: issue does not affect synchronization

(M)oderate: issue is likely to affect synchronization

(S)evere: issue stops synchronization and can normally be fixed locally

(C)ritical: issue stops synchronization and cannot be fixed locally

 

Sync Engine errors troubleshooting table

Error code Severity Cause(s) Solution
SC0001 M Key field:{ ‘:(field name)’:}:{ for type ‘:(type name)’:} does not exist or is not supported Contact us, describing the issue in detail
SC0002 L Unable to synchronize because both storages declare the ‘provide object-state’ procedure Contact us, describing the issue in detail
SC0003 L Both storages support up-syncing Contact us, describing the issue in detail
SC0004 L Both storages provide read-only records Contact us, describing the issue in detail
SC0005 L Setting states for read-only records is not permitted Contact us, describing the issue in detail
SC0006 L Removing unmatched records for read-only records is not permitted:{ (type: ‘:(type name)’):} Contact us, describing the issue in detail
SC0007 L Link restoring is not permitted for read-only records:{ (type: ‘:(type name)’):} Contact us, describing the issue in detail
SC0008 L Orphan cleanup is not permitted for read-only records:{ (type: ‘:(type name)’, link field: ‘:(link name)’):} Contact us, describing the issue in detail
SC0009 L Neither storage supports up-syncing Contact us, describing the issue in detail
SC0010 S The type:{ ‘:(type name)’:} was not found among synchronization types Contact us, describing the issue in detail
SC0011 S Snapshot creator support is specified in storage features, but no actual support is detected Contact us, describing the issue in detail
SC0012 L Custom deduplicator expected Contact us, describing the issue in detail
SC0013 L Maximum query length (max_query_size parameter) is set to zero for the custom deduplicator Contact us, describing the issue in detail
SC0014 C Undefined state is not permitted for records:{ (object id ‘:(object id)’):} Contact us, describing the issue in detail
SC0015 C Unknown record type:{: ‘:(type name)’:} Contact us, describing the issue in detail
SC0016 M Merge conflicts resolution is not permitted:{for ‘:(type name)’:} Contact us, describing the issue in detail
SC0017 M Synchronization scheme contains duplicate types:{: :(type name):} Contact us, describing the issue in detail
SC0018 M Synchronization type:{ ‘:(type name)’:} contains duplicate links:{: :(link name):} Contact us, describing the issue in detail
SC0019 M No fields were found in the natural key of synchronization type:{ ‘:(type name)’:} Contact us, describing the issue in detail
SC0020 M Synchronization type:{ ‘:(type name)’:} contains duplicate fields in the natural key:{: :(field name):} Contact us, describing the issue in detail
SC0021 reserved
SC0022 L Exclusions processing is not permitted for external snapshot creator Contact us, describing the issue in detail
SC0023 L Limiting the number of snapshot records is not permitted for external snapshot creator Contact us, describing the issue in detail
SC0024 L Declaring the ‘support frequency’ feature is not allowed for external snapshot creator:{ (type: ‘:(type name)’):} Contact us, describing the issue in detail
SC0025 L Wrong custom object state was detected:{ (state: ‘:(name)’, value: :(value)):} Check your synchronized data and resync
Error code Severity Cause(s) Solution
SD0000 C Record already synchronized:{: ‘:(object id)’:}:{ in ‘:(storage id)’:} Contact us, describing the issue in detail
SD0001 L Record type mismatch:{ ‘:(type name)’:}:{ vs. ‘:(existing type)’:}:{ for ‘:(object id)’:}:{ in ‘:(storage id)’:} Contact us, describing the issue in detail
SD0002 M Additional affiliates (values for link fields in object info) were detected for:{ ‘:(type name)’:} object:{ (id=’:(object id)’):} Contact us, describing the issue in detail
SD0003 C Returned fields number:{ (:(returned amount)):} is not equal to the number of requested fields:{ (:(requested amount)):}:{ for object ‘:(object id)’:} Contact us, describing the issue in detail
SD0004 C Unknown duplicate source record:{ (:(object id)):} Contact us, describing the issue in detail
SD0005 C Type specified by deduplicator differs from type provided by sync engine for the following record:{ (:(object id)):} Contact us, describing the issue in detail
SD0006 L Record:{ ‘:(object id)’:}:{ in storage ‘:(storage id)’:} was not found Contact us, describing the issue in detail
SD0007 C Returned:{ ‘:(type name)’:} records number:{ (:(returned amount)):} does not equal to requested records number:{ (:(requested amount)):} Contact us, describing the issue in detail
SD0008 C Returned fields number:{ (:(returned amount)):} does not equal to requested fields number:{ (:(requested amount)):}:{ for object ‘:(object id)’:} Contact us, describing the issue in detail
SD0009 C Duplicate IDs were detected for the following records:{: ‘:(object id)’:} Contact us, describing the issue in detail
SD0010 C Reused record identifier was detected:{ (reused id ‘:(object id)’):} Contact us, describing the issue in detail
SD0011 C Invalid filter criteria were detected:{ (:(value)):}
SD0012 C Types mismatch:{ for ‘:(object id)’:}:{: ‘:(type name)’ and ‘:(existing type)’:} Contact us, describing the issue in detail
SD0013 C Duplicate record:{ id ‘:(object id)’:}:{ of ‘:(type name)’:} Contact us, describing the issue in detail
SD0014 C The :{‘:(type name)’ :} object identifier cannot be empty Contact us, describing the issue in detail
SD0015 C The :{‘:(type name)’ :}object identifier cannot be set to a value that indicates a broken link Contact us, describing the issue in detail
SD0016 C The :{‘:(type name)’ :}object:{ (:(object id)):} affiliate:{ #:(index):} identifier cannot be empty Contact us, describing the issue in detail
SD0017 C The :{‘:(type name)’ :}object:{ (:(object id)):} affiliate:{ #:(index):} identifier cannot be set to a value that indicates a broken link Contact us, describing the issue in detail
SD0018 C The :{‘:(type name)’ :}object:{ (:(object id)):} affiliate:{ #:(index):} type cannot be empty Contact us, describing the issue in detail
SD0019 L Maximum snapshot records limit is exceeded:{ (:(limit)/:(total)/:(pinned)):} Change filters or unpin some objects in Customization settings, then resync
SD0020 C The meta_descriptor type:{ ‘:(type name)’:} contains duplicate fields:{: :(field name):} Contact us, describing the issue in detail
SD0021 C Created snapshot is not integral:{: :(value) unresolved objects:} Contact us, describing the issue in detail
SD0022 C Failed to retrieve the records of the following type:{ ‘:(type name)’:}:{ (requested: :(requested amount), returned: :(returned amount), inaccessible: :(inaccessible amount)):} Contact us, describing the issue in detail
SD0023 M Reverting changes is not applicable for record (:{object id ‘:(object id)’:}:{ from ‘:(storage id)’:}) Contact us, describing the issue in detail
SD0024 reserved
SD0025 M Synchronization was stopped in order to prevent creation of duplicates for the following item(s):{ (:(total)):}: :{:(object id 0) in :(storage id 0):}:{:(object id 1) in :(storage id 1):}:{:(object id 2) in :(storage id 2):}:{:(object id 3) in :(storage id 3):}:{:(object id 4) in :(storage id 4):}. Please check if any other synchronization solution is running and disable it. To resume sync, modify/delete objects causing duplications and resume sync. Check your synchronized data and resync
Error code Severity Cause(s) Solution
SE0001 L Adding read-only records is not allowed Check your synchronized data and resync
SE0002 L Parent record was not added:{ (link field ‘:(link name)’):} Check your synchronized data and resync
SE0003 M Reused record identifier detected:{ (reused id ‘:(object id)’):} Check your synchronized data and resync
SE0004 L Target record from post-update list was not found:{ (object id ‘:(object id)’):} Check your synchronized data and resync
SE0005 L Target record from post-update list was updated prematurely:{ (object id ‘:(object id)’):} Check your synchronized data and resync
Error code Severity Cause(s) Solution
SI0001 L The query_objects method is not implemented for stale_requestor Contact us, describing the issue in detail
SI0006 L Local_id:{ ‘:(object id)’:} does not exist Check your synchronized data and resync
SI0007 L Columns:{ ‘:(field name)’:} already exist Check your synchronized data and resync
SI0008 L Field:{ ‘:(field name)’:} does not exist Check your synchronized data and resync
SI0009 L Invalid VARIANT passed Check your synchronized data and resync
SI0010 L Invalid base passed Check your synchronized data and resync
SI0011 L Values count must match column size:{ :(value):}! Check your synchronized data and resync
SI0012 L The job requested to run has already been completed n/a
SI0013 L Synchronization failed to complete Check Issues tab in Sync dashboard for conflicts for more information
Error code Severity Cause(s) Solution
SW0000 L Synchronization was completed successfully n/a
SW0001 L Synchronization was interrupted by user or by LinkPoint Connect(ME) If this code appears not on user terminating sync manually but on sync session timeout (it is set to 1 hour by default), please Contact us to get the timeout value increased
SW0002 M Detected: :{:(conflicts amount):} conflict(s), :{:(duplicates amount):} duplicate(s), :{:(issues amount):} issue(s), :{:(confirmations amount):} confirmation(s) Check Issues tab in Sync dashboard for conflicts for more information
SW0003 S Unknown internal error occurred Contact us, describing the issue in detail
SW0004 M Detected: :{:(conflicts amount):} conflict(s), :{:(duplicates amount):} duplicate(s), :{:(confirmations amount):} confirmation(s) Check Issues tab in Sync dashboard for conflicts for more information

   


Get back to us